ICU Ventilator Emergency Medical Breathing Respiratory Ventilator

Customization: Available
Type: Ventilator
Used for: Adult

Product Description

Basic Specifications

Model NO.AM-900B
Size10.4''
CertificationCE, ISO13485
LCD Displaywith LCD Display
SourceOxygen
AnesthesiaSemi Open Suction
KindSurgical
GroupAll
Transport PackageCarton
OriginChina
HS Code90192000

ICU Ventilator Series

ICU Ventilator AM-900B (Flexible Configurations)

Advanced microprocessor-controlled ICU ventilator, pneumatically driven and electronically controlled, designed for both adult and pediatric respiratory support.

Key Features & Technical Specifications
  • Display: 10.4" TFT display screen for comprehensive ventilation parameters.
  • Power Source: Built-in backup battery supports operation for at least 4 hours.
  • Humidifier: Integrated humidifier with precise temperature adjustment.
  • Breathing Modes: A/C, SIPPV(VCV), IPPV(VCV), SIMV, PSIMV, CPAP, PCV, PEEP, SIGN, SPONT, MANUAL.
  • Tidal Volume Range: Adjustable from 20 to 1500ml (Display range up to 2000ml).
  • Respiration Frequency: 1 ~ 99 bpm; IMV Frequency: 1 ~ 20 bpm.
  • I/E Ratio: 4:1 ~ 1:4 flexible adjustment.
  • Safety: Maximum Safe Pressure ≤6.0 kPa with Pressure Limited range of 1.0kPa~ 6.0kPa.
  • Oxygen Concentration: 21% ~ 100% adjustment capability.
  • Trigger Methods: Supports both Pressure and Volume triggering.

Ventilation Monitoring

The system provides real-time monitoring of essential parameters to ensure patient safety:

  • Tidal volume, Minute ventilation, and Frequency monitoring.
  • Airway Pressure, I/E ratio, and Inspiration time tracking.
  • PEEP, FiO2, PCV, and PSV data display.
  • High-resolution waveforms for Time-Airway Pressure and related respiratory dynamics.
Technical Layout
Specification Chart
Detailed Technical Data

Frequently Asked Questions

1. Which patient groups is the AM-900B suitable for?
The AM-900B ICU Ventilator is designed for versatile clinical use and is suitable for both Adult and Pediatric patients.
2. How long does the backup battery last?
The built-in backup battery is designed for reliability, providing at least 4 hours of continuous operation in case of power failure.
3. Does the system include an air compressor?
The AM-900B can be configured with or without a medical-grade air compressor depending on the specific facility requirements.
4. What type of display screen does it use?
It features a 10.4" TFT color display screen that clearly shows all vital ventilation parameters and waveforms.
5. What are the available ventilation modes?
The system supports multiple modes including A/C, SIPPV, IPPV, SIMV, PSIMV, CPAP, PCV, PEEP, SIGN, SPONT, and MANUAL modes.
6. What is the adjustable range for Tidal Volume?
The adjustable range for Tidal Volume is 20ml to 1500ml, making it flexible for various respiratory treatment needs.

Related Products