Infant Resuscitator, Infant Ventilator, Infant Emergency Ventilator

Customization: Available
Type: Emergency Ventilator
Used for: Adult, Child

Product Description

Basic Information
Model NO.
AD3000-TPB
Transport Package
Carton
Specification
57*57*36cm
Origin
China
HS Code
9019200090
Capacity
50 units/Month
Product Description
Intended Use: Mainly used in delivery rooms, baby wards, and NICU for infants with a maximum weight up to 10KG.
  • Precise Oxygen Control: Adjust oxygen concentration from 21% to 100% by adjusting the proportion of oxygen and air.
  • Safety Alarm System: Integrated differential pressure alarm. If triggered, the safety valve starts automatically to ensure continuous mixture gas flow.
  • Controlled Resuscitation: MAX-P and PIP are safe, controlled, and accurate for infant safety.
  • Constant PEEP: Ensures accurate and consistent Positive End-Expiratory Pressure.
  • Operator Independent: Output pressure is not influenced by the operator's experience, training, or fatigue.
  • Flexible Application: Simple operation suitable for temporary breathing support.
Technical Specifications
Flow Control5LPM ~ 15LPM
Oxygen Concentration21% ~ 100%
Pressure Gauge Range-2 ~ 10KPa (-20 ~ 100cmH2O)
MAX-P≤ 6kPa (60cmH2O) @ 0~15LPM
PIP0.2 ~ 5.7kPa (2 ~ 57cmH2O) @ 5~15LPM
PEEP0.03 ~ 2.3kPa (0.3 ~ 23cmH2O) @ 5~15LPM
Air Supply AlarmInterruption or diff > 0.1MPa (Sound > 60dB, min 60s)
Working Noise≤ 55dB(A)
Weight RangeMax. 10KG
Quality CertificationISO 13485
Frequently Asked Questions
What is the maximum weight capacity for this resuscitator?
The AD3000-TPB Infant Resuscitator is specifically designed for babies weighing up to 10KG.
In which medical settings can this device be used?
It is primarily used in delivery rooms, infant wards, and Neonatal Intensive Care Units (NICU).
Can the oxygen concentration be adjusted?
Yes, the oxygen concentration is fully adjustable from 21% to 100% by managing the air and oxygen proportions.
How does the alarm system function?
The device features a differential pressure alarm. If the air source is interrupted or pressure difference exceeds 0.1MPa, a sound alarm (>60dB) will trigger for at least 60 seconds.
Is the output pressure consistent regardless of the operator?
Yes, one of the key safety features is that the output pressure (MAX-P, PIP, and PEEP) is controlled by the device and is not influenced by the operator's experience or fatigue.
What quality certifications does the product hold?
The product is manufactured under ISO 13485 quality certification standards for medical devices.