Medical Hospital Clinic Surgery Equipment PA-900b Critical Care ICU Ventilator Machine

Customization: Available
Display: 10.4 Inch High Visibility Color TFT Display
Simv Rate: 1-20bpm

Product Description

Basic Information

Model NO.
PA-900B
Inspiratory Pressure
-10-10CMH2o
Peep
0-10CMH2o
Oxygen Concentration
21-100%
Kind
Operation Room
Inspiratory Time
0.1-2.0s
Sigh
1-8 Per 100 Breaths
Trigger Sensitivity
-10-10CMH2o
Tidal Volume
20-1500ml
Transport Package
Standard Export Carton
Specification
L60*W50*H120CM, 44KG
Origin
China
Medical Hospital Clinic Surgery Equipment PA-900B Critical Care ICU Ventilator Machine
Critical Care ICU Ventilator Machine
PA-900B Ventilator Detail

Common Features

  • Operating Modes: Pneumatically driven & electronically controlled, closed, semi-closed and semi-open
  • Pneumatically driven electrically controlled ventilator, can be used for emergency clinical resuscitation and respiratory therapy
  • Display: Built-in 10.4 inch color TFT fully adjustable display, able-display Pressure-Time, Frequency-Time, Pressure-Volume, Frequency-Volume and any two waveforms simultaneously on screen
  • Trigger Types: Pressure trigger, Flow trigger
  • Sigh: Ability to insert 1-8 sigh breaths in every 100 breaths, ventilation should be no less than 1.5 the tidal volume
  • Features built-in dual electronic flow sensors and dual respiratory modules
  • Power Failure Support Functions: Automatically converts-standby mode during AC power outages
  • Monitor Parameters: tidal volume, respiration rate, airway pressure, I:E ratio, inspiratory & expiratory status, inspiratory trigger and others
  • Equipped with infrared turbine flow sensor; precisely measures gas flows, stable and reliable
  • Nine Level adjustable humidifier
  • Nonhazardous environmentally friendly frame, precise construction, elegant design, equipped with automated self-checking function during startup and an automatic self-calibrating sensor
  • Alarms: Audible and/or visual alarms for ventilation volume, tidal volume, oxygen concentration, asphyxia, airway pressure, intubation disconnection, low oxygen, power failure and other alarms

Advanced Model Exclusive Features

  • Equipped with professional medical grade air compressor tailored for long clinical times and low noise requirements
  • Air Compressor: 220V AC±10%, 50±1Hz, 700VA, features protective grounding
  • Output Gas Pressure: 0.4MPa±20%
  • Continuous output gas flow ≥ 20L/min; Instantaneous output gas flow ≥ 60L/min
Advanced Model Compressor

Specifications

ModelPA-900B (Advanced Model)
Display10.4 inch high visibility color TFT display
Ventilation ModeA/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, SPONT MANUAL
Minute VolumeGreater than or equal to 18L
Back-up Power SupplyAt least 4 hours
Tidal VolumeAdjustable range: 20-1500ml, Display range: 0-2000ml
Respiratory Rate1-99bpm
I:E Ratio4:1-1:4
PEEP0-10cmH2O
SIMV Rate1-20bpm
Oxygen Concentration21-100%
Pressure Limit1.0kPa~6.0kPa
Ventilator Interface
ICU Setup

Frequently Asked Questions

What types of ventilation modes does the PA-900B support?
The PA-900B supports a comprehensive range of modes including A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, and SPONT MANUAL.
How long can the ventilator operate during a power failure?
It is equipped with a back-up power supply that ensures the machine can continue operating for at least 4 hours.
Is the display adjustable for better visibility?
Yes, the device features a built-in 10.4-inch color TFT display that is fully adjustable and provides high visibility for monitoring waveforms and parameters.
What is the tidal volume range for this ICU ventilator?
The tidal volume is highly adjustable, ranging from 20ml to 1500ml, making it suitable for a wide range of patient needs.
Does the advanced model include an air compressor?
Yes, the PA-900B Advanced Model comes with a professional medical-grade air compressor designed for low noise and long clinical operation times.
What kind of alarm systems are integrated into the device?
It includes both audible and visual alarms for ventilation volume, tidal volume, oxygen concentration, airway pressure, asphyxia, and power failure.