PA-100d Medical Hospital Respiratory ICU Portable Breathing Transport Ventilator

Customization: Available
Type: Ventilator
Tidal Volume: 50~2000 Ml

Product Description

📋

Basic Specifications

Model NO.
PA-100D
Oxygen Concentrator
45~100%
Applications
Transport Patient, Ambulance
Certification
CE, ISO13485
Transport Package
Export Packing
Production Capacity
100 units/Week
🏥

Product Overview

PA-100D Medical ICU Portable Ventilator is a high-performance respiratory support system designed for critical care and emergency transport. It provides reliable ventilation with precise control over tidal volume and oxygen concentration.

Key Features:
🔹 Versatile Range: Tidal Volume from 50 to 2000 ml.
🔹 Advanced Display: Large LCD for real-time data & curves.
🔹 Safety First: Comprehensive alarm system for pressure and power.
🔹 High Precision: Synchronized trigger and PEEP control.
📊

Technical Parameters

Tidal Volume50~2000 ml
Respiratory Rate1~100 bpm
O2%45~100%
Trigger Level-20~0 hpa
Peak Pressure0~60 hPa
PEEP0~20 hPa
SIGH1~10 times per 100 breath
Large LCD Screen Data DisplayTidal Volume, O2%, Sigh, Respiratory Rate, Flow, Pressure (Synchronized Trigger, Peak Airway, CPAP, PEEP)
Large LCD Screen Curve DisplayAirway Pressure Time Waveform Display
Alarm Data DisplayHigh/Low Airway Pressure Alarm, Lack of Gas/Power Alarm, Parameter Error
🖼️

Product Gallery

Frequently Asked Questions
What is the tidal volume range of the PA-100D ventilator?
The PA-100D offers a wide tidal volume range from 50 ml to 2000 ml, making it suitable for a variety of patient needs.
Can this ventilator be used in an ambulance?
Yes, its portable design and robust specifications make it ideal for transport patients and emergency ambulance applications.
Does the device display real-time pressure waveforms?
Yes, the large LCD screen features a curve display for airway pressure time waveforms, allowing medical professionals to monitor breathing patterns accurately.
What kind of alarms are integrated into the system?
The ventilator includes alarms for high/low airway pressure, gas or power failure, and parameter configuration errors to ensure patient safety.
Is the oxygen concentration adjustable?
Absolutely. The oxygen concentration (O2%) can be adjusted between 45% and 100% depending on the clinical requirement.
What certifications does the PA-100D hold?
This medical ventilator is fully certified with CE and ISO13485 standards, meeting international quality and safety requirements.

Related Products